Product Description: Allen-Bradley 440R-S13R2

The Allen-Bradley 440R-S13R2 is a Minotaur safety relay designed to monitor safety devices such as emergency stop buttons, safety gates, and light curtains. It features dual-channel input capability with redundant relay outputs for reliable fail-safe operation. This unit ensures machine safety by removing power to hazards when a fault or stop condition is detected. Its compact design allows easy integration into control panels while meeting international safety standards.

Key Features

  • Dual-channel input monitoring for safety devices
  • 2 normally open (N.O.) redundant safety relay outputs
  • 1 normally closed (N.C.) auxiliary output for diagnostics
  • Automatic or manual/manual monitored reset options
  • LED indicators for status and diagnostics
  • SIL 3 / PLe / Cat. 4 rated
  • Compact DIN rail mountable housing
  • Screw terminal connections for secure wiring
  • Suitable for use in applications requiring stop category 0 or 1

Technical Specifications

  • Supply Voltage: 24V AC/DC
  • Input Channels: Dual-channel (dry contact or PNP)
  • Safety Outputs: 2 N.O. relay outputs
  • Auxiliary Outputs: 1 N.C. relay output
  • Output Contact Rating: 250V AC / 6A (resistive load)
  • Power Consumption: ~3.5 W
  • Response Time: Typically < 30 ms
  • Electrical Life: ≥ 100,000 operations at full load
  • Mounting: DIN rail
  • Enclosure Rating: IP40 (housing), IP20 (terminals)
  • Operating Temperature: -10°C to +55°C
  • Dimensions (H x W x D): Approx. 99 mm x 22.5 mm x 114.5 mm

Application Areas

  • Emergency stop circuits
  • Guard monitoring systems
  • Light curtain and safety mat integration
  • Presses, packaging, and cutting machines
  • Robotics and automated equipment
  • Functional safety circuits requiring redundant logic

Advantages

  • Provides high- integrity safety monitoring for critical devices
  • Dual-channel input ensures redundancy and fault detection
  • Supports flexible reset configurations to suit various applications
  • Compact footprint saves panel space
  • Easy to install and configure with diagnostic indicators
  • Certified to global safety standards for machine control